Fluke 500 Series Battery Analyzer |
Range | Resolution | Accuracy | BT510 | BT520 | BT520ANG | BT521 | BT521ANG | |
Battery Resistance / Strap Resistance1 | 3 mΩ | 0.001 mΩ | 1% + 8 | √ | √ | √ | ||
1% +68 | √ | √ | ||||||
30 mΩ | 0.01 mΩ | 0.8% + 6 | √ | √ | √ | |||
0.8%+12 | √ | √ | ||||||
300 mΩ | 0.1 mΩ | 0.8% + 6 | √ | √ | √ | √ | √ | |
3000 mΩ | 1 mΩ | 0.8% + 6 | √ | √ | √ | √ | √ | |
VDC | 6 V | 0.001 V | 0.09% + 5 | √ | √ | √ | √ | √ |
60 V | 0.01 V | 0.09% + 5 | √ | √ | √ | √ | √ | |
600 V | 0.1 V | 0.09% + 5 | √ | √ | √ | √ | √ | |
1000 V | 1 V | 0.09% + 5 | √ | √ | ||||
600 V | 0.1 V | 2% + 10 | √ | √ | √ | √ | √ | |
Frequency (displayed with VAC and AAC)2 | 500 Hz | 0.1 Hz | 0.5% + 8 | √ | √ | √ | √ | √ |
AC voltage ripple (20 KHz Max) | 600 mV | 0.1 mV | 3% + 20 | √ | √ | √ | √ | √ |
6000 mV | 1 mV | 3% + 10 | √ | √ | √ | √ | √ | |
ADC/AAC (with accessory Fluke i410) | 400 A | 1 A | 3.5% + 2 | √ | √ | |||
Temperature | 0°C to 60°C | 1°C | 2°C (4°F) | √ | √ | |||
Meter mode | 999 records for each measurement position with time stamp | |||||||
Sequence mode | Up to 100 profiles and 100 profile templates (Each profile stores up to 450 batteries) with time stamp | |||||||
1. The measurement is based on AC injection method. The injected source signal is < 100 mA, 1 kHz. 2. Trigger level VAC: 10 mV, AAC: 10 A |
||||||||
Measurement Modes | BT510 | BT520 | BT521 | |||||
Resistance (mΩ) | √ | √ | √ | |||||
Battery voltage | √ | √ | √ | |||||
Voltage DC | √ | √ | √ | |||||
Voltage AC and frequency (Hz) | √ | √ | √ | |||||
Ripple volt | √ | √ | √ | |||||
Temperature of negative battery post (using BTL21 straight probes) | √ | |||||||
DC and AC current (and frequency) | √ | |||||||
DMM mode | √ | √ | √ | |||||
Sequence mode | √ | √ | √ | |||||
Discharge measurement mode | √ | √ | √ | |||||
Automatic measurement save | √ | √ | √ | |||||
Wireless communication | √ | |||||||
Memory view | √ | √ | √ | |||||
General Specifications - Battery Analyzer | ||||||||
Size (H x W x D) | 22 x 10.3 x 5.8 cm (9 x 4 x 2 in) | |||||||
Weight | 850 g (1.9 lb) | |||||||
Screen dimensions | 7.7 x 5.6 cm (3 x 2.2 in) | |||||||
Interface | USB mini | |||||||
Warranty | 3 years | |||||||
General Specifications - BTL20ANG Angled Measurement Probe | ||||||||
Long angled probe (overall length) | 242.2 cm (95.38 in) | |||||||
Short angled probe (overall length) | 216.8 cm (85.38 in) | |||||||
Overall span (coil relaxed) | 10.1 cm (4 in) | |||||||
Overall maximum span (coil extended) | 109.2 cm (43 in) | |||||||
BTL20ANG probe tip angle | 20 degrees from horizontal | |||||||
Environment Specifications | ||||||||
Operating temperature | 0°C to 40°C | |||||||
Storage temperature | -20°C to 50°C | |||||||
Lithium-ion battery charging temperature | 0°C to 40°C | |||||||
Operating humidity | Non-condensing (10°C) | |||||||
≤ 80% RH (at 10°C to 30°C) | ||||||||
≤ 75% RH (at 30°C to 40°C) | ||||||||
Operating altitude | Sea level to 2000 meters | |||||||
Storage altitude | Sea level to 12,000 meters | |||||||
IP rating | IP40 | |||||||
Radio | FCC Class A | |||||||
Vibration requirements | MIL-PRF-28800F: Class 2 | |||||||
Drop test requirements | 1 meter | |||||||
Temperature coefficients | Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C | |||||||
Safety compliance | 600 V CAT III | |||||||
EMC | IEC 61326 | |||||||
ROHS | China, Europe | |||||||
Protection class 2 | Pollution Degree II | |||||||
Battery compliance | UN38.3 | |||||||
UL2054 | ||||||||
IEC62133 | ||||||||
2 G per IEC68-2-26, 25 G, and 29 |